VARTA.wall | Installation & VARTA.install

VARTA.install

Simple installation via app

Quick commissioning of the VARTA.wall in under 10 minutes

Simple step-by-step instructions

Compatible with iOS, Android and Microsoft devices

Delivery and transport instructions

Proper transport and storage for a long-lasting, intact battery

Packaging

Master and base unit are delivered together in one box, battery modules are packed individually

Always transport the storage units in the original carton with hazardous goods labelling and check the packaging for transport damage

What to do in the event of transport damage?
  • Document the damage on the delivery note and have this confirmed by signature
  • Reject deliveries with severe damage
  • Inform your supplier immediately
  • Damaged modules must not be installed


Transport

Lithium-ion cells are dangerous goods, the German Dangerous Goods Transport Act (GGBefG, national regulations) applies
 

Craftsmen may transport a maximum of 1,000 hazardous goods points. This corresponds to 9 modules of the VARTA.wall.

Storage

The products (battery modules, master unit, base unit) must be installed by a qualified and VARTA-certified electrician within 12 months of the production date (see the label on the packaging).

Storage time at constant temperature and dry environment:

  • At -20 to +50 °C: less than 1 month
  • At -20 to +35 °C: less than 3 months